TM 9-2350-287-20-1
2-19. TROUBLESHOOTING CHART (continued).
g GAGES (continued).
(1) ENGINE OIL PRESSURE GAGE FAILS TO
OPERATE WITH ENGINE RUNNING. All other
gages operate properly (continued).
Repair lead 36 or replace harness
12268418-1 (para 7-44) Verify problem is
solved.
F. 1. Disconnect harness 12260298 at discon-
nect bracket.
2. Place one multimeter lead in harness
12260287 socket J at drivers bulkhead dis-
connect and other lead on harness 12260287
pin D at disconnect bracket.
3. Check for continuity
Is continuity present?
Repair lead 36 or replace harness
12260287 (para 7-56). Verify problem is
solved.
Repair lead 36 or replace harness
12260298 (para 7-7). Verify problem is
solved.
END OF TASK
2-102