TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).g GAGES (continued).(1) ENGINE OIL PRESSURE GAGE FAILS TOOPERATE WITH ENGINE RUNNING. All othergages operate properly (continued).Repair lead 36 or replace harness12268418-1 (para 7-44) Verify problem issolved.F. 1. Disconnect harness 12260298 at discon-nect bracket.2. Place one multimeter lead in harness12260287 socket J at driver’s bulkhead dis-connect and other lead on harness 12260287pin D at disconnect bracket.3. Check for continuityIs continuity present?Repair lead 36 or replace harness12260287 (para 7-56). Verify problem issolved.Repair lead 36 or replace harness12260298 (para 7-7). Verify problem issolved.END OF TASK2-102