TM 9-2350-287-20-112-19. TROUBLESHOOTING CHART (continued).d. ENGINE - ELECTRICAL SYSTEM (continued).(3) ENGINE CRANKS, BUT WILL NOT START(continued).ICONTINUED FROM STEP CIG. 1. Reconnect wire 76 to FUEL PRIME PUMPswitch.2. Disconnect lead assembly 12353646 con-nector from in-tank fuel pumps and generatorsystem relay.3. Place multimeter red lead in socket A ofconnector and ground black lead.4. Turn MASTER switch ON (refer to TM 9-2350-287-1 O) and check socket A for voltage(24 ± 3 VdC.)5. Repeat voltage check for socket B (24 ±vdc) .6. Turn MASTER switch OFF (refer to TM 9-2350-287-1 O).Is voltage present in both sockets?GO TO STEP JIH. 1. Reconnect connect or to in-tank fuel pumpsand generator system relay.2. Disconnect wire 10 from Y connector.3. Place multimeter red lead in Y connectorand ground black lead.4. Turn MASTER switch ON (refer to TM 9-2350-287-10) and check Y connector for volt-age (24 ± 3 vdc).5. Turn MASTER switch OFF (refer to TM 9-2350-287-10).Is voltage present?LEADASSEMBLY12353646Continued on next page2-66