TM 9-2350-287-20-1
12-19. TROUBLESHOOTING CHART (continued).
d. ENGINE - ELECTRICAL SYSTEM (continued).
(3) ENGINE CRANKS, BUT WILL NOT START
(continued).
I
CONTINUED FROM STEP C
I
G. 1. Reconnect wire 76 to FUEL PRIME PUMP
switch.
2. Disconnect lead assembly 12353646 con-
nector from in-tank fuel pumps and generator
system relay.
3. Place multimeter red lead in socket A of
connector and ground black lead.
4. Turn MASTER switch ON (refer to TM 9-
2350-287-1 O) and check socket A for voltage
(24 ± 3 VdC.)
5. Repeat voltage check for socket B (24 ±
vdc) .
6. Turn MASTER switch OFF (refer to TM 9-
2350-287-1 O).
Is voltage present in both sockets?
GO TO STEP J
I
H. 1. Reconnect connect or to in-tank fuel pumps
and generator system relay.
2. Disconnect wire 10 from Y connector.
3. Place multimeter red lead in Y connector
and ground black lead.
4. Turn MASTER switch ON (refer to TM 9-
2350-287-10) and check Y connector for volt-
age (24 ± 3 vdc).
5. Turn MASTER switch OFF (refer to TM 9-
2350-287-10).
Is voltage present?
LEAD
ASSEMBLY
12353646
Continued on next page
2-66