TM 9-2350-287-10OPERATING THE APU (continued)12. If batteries in supported vehicle activate gages or lights unaided by the APU, chargebattery as follows:a.Turn MASTER switch to ON in your vehicle.b.Start the APU (p. 2-118).c.Turn on APU GENerator switch (7).d.Turn MASTER switch to ON in supported vehicle. Batteries will charge.e.Continue to charge batteries until charge indicator in supported vehicle reads wellinto normal range.CAUTIONl Do not attempt to start disabled vehicle with power fromAPU STARTER/GENERATOR. Doing this can causedamage to APU STARTER/GENERATOR. The APU is forrecharging purposes during slaving procedures only.l Be sure APU GENerator switch is off before turning APUFUEL SHUT OFF switch to OFF.13. Turn APU FUEL SHUT OFF switch (6) to OFF.14.15.WARNINGTo avoid injury, turn off MASTERswitches in both vehicles beforedisconnecting slave cable.Turn MASTERvehicle.Disconnect andswitch to OFF in eachstow slave cable.2-130