ASSEMBLY
1.
Install four connectors (1), dust caps (2), on cover (3) and secure with sixteen screws (4) and new locknuts (5).
2.
Install connector J1 (6) on extension box (7) and secure with four screws (8) and new locknuts (9).
3.
Connect leads to connectors if necessary.
4.
Install gasket (10), cover (3), on extension box (7) and secure with four screws (11).
NOTE
Color Designation for Terminals:
H (HOT) = YELLOW
N (NEUTRAL) = WHITE
G (GROUND) = GREEN
0097 00-3