TM 9-2350-277-34
REPLACE ENGINE Continued
0015 00
69. Connect harness lead (1) to pulse tachometer (2).
70. Connect lead (3) to fuel return pressure switch (4).
71. Connect lead (5) to turbo outlet pressure switch (6).
CAUTION
Excess heat can cause the fuel return pressure switch to leak. Leaking fuel can catch fire and
cause equipment damage. Make sure electrical lead is secured away from exhaust duct.
72. Secure new tie strap (7).
73. Install leads (8) on starter solenoid (9) terminals. Secure with two nuts (10) and new lockwashers (11).
0015 00-37