TM 9-2350-277-20-6
REPLACE CHEMICAL ALARM JUNCTION BOX/POWER CABLE/ALARM CABLE
(M113A3 ONLY) Continued
0919 00
7.
Disconnect power cable (6) plug 6B POS (7) from socket (8).
8.
Remove screw (9), lockwasher (10), clamp (11) with cable (12), power cable (6), ground lead (13), two ground leads
(14), capacitor bracket (15), and lockwasher (16) from weldnut (17). Discard lockwashers.
0919 00-5