TM 9-2350-277-20-6
REPLACE CHEMICAL ALARM JUNCTION BOX/POWER CABLE/ALARM
CABLE (M113A3 ONLY)
0919 00
THIS WORK PACKAGE COVERS:
Removal (page 0919 00-1).
Inspection (page 0919 00-6).
Repair or Replacement (page 0919 00-7).
Installation (page 0919 00-7).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit WP 0926 00, Item 65
Multimeter WP 0926 00, Item 30
Materials/Parts
Lockwasher (2)
Personnel Required
Unit Mechanic
References
See your -10
TM 3-6665-274-20
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Battery ground strap disconnected (WP 0919 00)
REMOVAL
NOTE
Move spall liners as required to gain access to junction box.
1.
Remove wiring harness plug (1) on cable (2) from jack on bottom of junction box (3).
0919 00-1