TM 9-2350-277-20-6REPLACE CHEMICAL ALARM JUNCTION BOX/POWER CABLE/ALARMCABLE (M113A3 ONLY)0919 00THIS WORK PACKAGE COVERS:Removal (page 0919 00-1).Inspection (page 0919 00-6).Repair or Replacement (page 0919 00-7).Installation (page 0919 00-7).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit WP 0926 00, Item 65Multimeter WP 0926 00, Item 30Materials/PartsLockwasher (2)Personnel RequiredUnit MechanicReferencesSee your -10TM 3-6665-274-20Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Battery ground strap disconnected (WP 0919 00)REMOVALNOTEMove spall liners as required to gain access to junction box.1. Remove wiring harness plug (1) on cable (2) from jack on bottom of junction box (3).0919 00-1