11. Insert lead (1) and lead (2) through grommets (3) in distribution box (4).
12. Install lead (1) and lead (2) on bus terminal (5). Secure with washer (6) and nut (7). TIGHTEN NUT TO 175 TO 195
LB-IN (20 TO 22 N m).
13. Install cover (8) on power distribution box. Close ten latches (9).
0913 00-14