TM 9-2350-277-20-6REPLACE/REPAIR VFM POWER DISTRIBUTION PANEL ASSEMBLY (M981A3 ONLY) —Continued0913 00NOTELubricate rubber-to-rubber mating surfaces with silicone compound.4. Connect lead assembly (18) to terminal 3 of connector J1 (19) and terminal 2 of switch S1 (20).5. Connect lead assembly (21) to terminal 2 of connector J1 (22) and terminal 1 of circuit breaker CB1 (23).6. Connect lead assembly (24) to terminal 3 of connector J2 (25) and terminal 1 of circuit breaker CB3 (26).7. Connect lead assembly (27) to terminal 2 of connector J2 (28) and terminal 2 of circuit breaker CB4 (29).8. Connect lead assembly (30) to terminal 3 of connector J3 (31) and terminal 2 of circuit CB1 (32).9. Connect lead assembly (33) to terminal 2 of connector J3 (34) and terminal 2 of circuit breaker CB2 (35).0913 00-11