TM 9-2350-277-20-6
REPLACE/REPAIR VFM POWER DISTRIBUTION PANEL ASSEMBLY (M981A3 ONLY)
Continued
0913 00
NOTE
Lubricate rubber-to-rubber mating surfaces with silicone compound.
4.
Connect lead assembly (18) to terminal 3 of connector J1 (19) and terminal 2 of switch S1 (20).
5.
Connect lead assembly (21) to terminal 2 of connector J1 (22) and terminal 1 of circuit breaker CB1 (23).
6.
Connect lead assembly (24) to terminal 3 of connector J2 (25) and terminal 1 of circuit breaker CB3 (26).
7.
Connect lead assembly (27) to terminal 2 of connector J2 (28) and terminal 2 of circuit breaker CB4 (29).
8.
Connect lead assembly (30) to terminal 3 of connector J3 (31) and terminal 2 of circuit CB1 (32).
9.
Connect lead assembly (33) to terminal 2 of connector J3 (34) and terminal 2 of circuit breaker CB2 (35).
0913 00-11