INSTALLATION
1.
Install RP1 harness (1), four screws (2), and new locknuts (3) on faceplate (4). Route RP1 harness leads down through
power enclosure (5) and behind inverter housing A2 to front face of inverters. Avoid interfering with other components
in power enclosure.
2.
Lift faceplate (4) in place and install 10 new lockwashers (6) and screws (7).
3.
Connect RP1 harness (1) to front of inverters (8). Tighten captive screws on connectors.
4.
Install face plate (9) on front of inverter housing A2 (10) with 10 new lockwashers (11) and screws (12).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0338 00).
END OF TASK
0847 00-3/4 blank