TM 9-2350-277-20-6REPLACE/REPAIR POWER DISTRIBUTION BOX A3 (M1068A3 ONLY) — Continued 0831 001. Disconnect cable (1) from connector (2) on power distribution box (3).2. Remove 12 screws (4), lockwashers (5), and lid (6) from power distribution box (3). Discard lockwashers.3. Remove screw (7), washer (8), and two circuit 1 leads (9) from terminal 1 (10).4. Remove screw (7), washer (8), and two circuit 2 leads (11) from terminal 2 (12).5. Remove screw (7), washer (8), and circuit 3 lead (13) from terminal 3 (14).6. Remove two screws (15), washers (16), and power distribution box (3) from bulkhead.0831 00-2