TM 9-2350-277-20-5REPLACE M14 NBC HEATER WIRING HARNESS (M113A3 AMBULANCEONLY)0807 00THIS WORK PACKAGE COVERS:Removal (page 0807 00-1).Installation (page 0807 00-4).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsStrap (as required)Personnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Battery ground strap disconnected (WP 0337 00)REMOVAL1. Cut and remove all straps (1) securing NBC wiring harness (2) to adjacent cables and hoses. Discard straps.2. Remove screw (3), washers (4), and ground lead (5) from regulator bracket (6).3. Disconnect NBC wiring harness (2) from NBC control box (7).4. Loosen screw (8) on air purifier resilient mount (9) and remove ground lead (10).0807 00-1