TM 9-2350-277-20-5REPLACE SMOKE GENERATOR FUEL LINES AND GUARDS (M1059A3 ONLY) —Continued0765 00NOTERemoving fuel line guard (4) will also loosen electrical line guard (5). Electrical line guardshould be held in place and not removed. Follow Step 2 below.2. Remove four screws (1), lockwashers (2), washers (3) and two fuel line guards (4) on fuel tanks. Discard lockwashers.3. To hold electrical line guard (5) in place, reinstall, but do not completely tighten, four screws (1) and washers (3) intoelectrical line guards.4. On left side of carrier, remove four screws (6), lockwashers (7), and ten clamps (8) from fuel lines. Discard lockwashers.5. On right side of carrier, remove five screws (9), lockwashers (10), and ten clamps (11) from fuel lines. Discardlockwashers.0765 00-2