TM 9-2350-277-20-5
REPLACE SMOKE GENERATOR FUEL LINES AND GUARDS (M1059A3 ONLY)
Continued
0765 00
NOTE
Removing fuel line guard (4) will also loosen electrical line guard (5). Electrical line guard
should be held in place and not removed. Follow Step 2 below.
2.
Remove four screws (1), lockwashers (2), washers (3) and two fuel line guards (4) on fuel tanks. Discard lockwashers.
3.
To hold electrical line guard (5) in place, reinstall, but do not completely tighten, four screws (1) and washers (3) into
electrical line guards.
4.
On left side of carrier, remove four screws (6), lockwashers (7), and ten clamps (8) from fuel lines. Discard lockwashers.
5.
On right side of carrier, remove five screws (9), lockwashers (10), and ten clamps (11) from fuel lines. Discard
lockwashers.
0765 00-2