TM 9-2350-277-20-5
REPLACE FOG OIL PUMP ASSEMBLY (M1059A3 ONLY) Continued
0763 00
6.
Remove 12 screws (10), lockwashers (11), washers (12), and pump assembly (7) from fog oil tank (13). Discard
lockwashers.
INSTALLATION
1.
Install fog oil pump assembly (1) on fog oil tank (2). Secure with 12 screws (3), new lockwashers (4), and washers (5).
2.
Connect cable assembly (6) to fog oil pump cable assembly (7).
3.
Install two strainers (8) on pump assembly (1).
4.
Connect two fog oil hoses (9) to two strainers (8).
5.
Remove safety caps (10) from two fog oil hoses (11) and dust caps (12) from two quick disconnect couplings (13).