TM 9-2350-277-20-5REPLACE COOLANT HEATER WIRING HARNESS 0735 00THIS WORK PACKAGE COVERS:Removal (page 0735 00-1).Installation (page 0735 00-4).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsTie down strap (2)Personnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Trim vane lowered (see your -10)Power plant access door opened (see your -10)Battery ground strap disconnected (WP 0337 00),(WP 0338 00), or (WP 0339 00)Coolant heater and pump unit removed (WP 0728 00)REMOVAL1. Disconnect main wiring harness 402A lead (1) from coolant heater wiring harness lead (2).2. Disconnect control box connector (3) from control box receptacle (4).3. Remove eight line straps (5) securing coolant heater wiring harness (6) to main wiring harness (7).0735 00-1