TM 9-2350-277-20-5REPLACE HEATER AIR INTAKE AND EXHAUST PIPES (ALL EXCEPT M1064A3) —Continued0682 00INSTALLATION1. If grommet (1) was discarded, install new grommet in power plant bulkhead.2. Install exhaust pipe (2) in grommet (1). Install exhaust pipe (3) on pipe (2).3. Align two exhaust pipes (3)(4) and two new bulkhead gaskets (5) with power plant bulkhead. Secure with four screws(6) and new locknuts (7).4. Place new elbow gasket (8) on exhaust elbow (9). Install elbow in top deck.5. Place new elbow gasket (8) on intake elbow (10). Install elbow in top deck.6. Secure two elbows (9)(10) to top deck with six screws (11).7. Secure pipe (4) to exhaust elbow (9) with U-bolt (12), clamp (13), and two nuts (14).8. Connect elbow (15) to intake elbow (10) and place clamp (16) on intake elbow (10).0682 00-3