TM 9-2350-277-20-4
ADJUST RAMP LOCK (M577A3 AND M1068A3 ONLY) Continued
0522 00
NOTE
After attaching clevis to the arm, make sure arm (3) is still against the setscrews.
9.
Align clevis (5) with arm (6). Secure with headed pin (7) and new cotter pin (8).
10. Loosen two nuts (9) on cable (10) at bracket (11).
11. Adjust length of cable (10) to obtain 1-7/8 inches (5 cm) clearance between nut (12) and seal (13). Tighten two nuts (9).
0522 00-4