TM 9-2350-277-20-3
REPLACE DIFFERENTIAL PRESSURE SWITCH AND BYPASS PLUG
0401 00
THIS WORK PACKAGE COVERS:
Removal (page 0401 00-1).
Installation (page 0401 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Preformed packing (2)
Preformed packing
Preformed packing
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Power plant access door open (see your -10)
REMOVAL
1.
Disconnect electrical connector (1) from switch (2) on filter head (3).
2.
Remove switch (2), packing (4), and packing (5) from filter head (3). Discard packings.
3.
Remove plug (6), packing (4), and packing (7) from filter head (3). Discard packings.
0401 00-1