5.
Place terminal lug (15) on negative battery post (16) and secure with screw (17) and nut (18).
6.
Align circuit 779 lead (9) on screw (19) in negative terminal lug (15).
7.
Install circuit 7 lead (13) on screw (19) in negative terminal lug (15). Secure with nut (20).
8.
Install new tiedown straps (21) on circuit 6P lead (22) and circuit 6N lead (23).
9.
Align five clamps (24) on weldnuts and secure with new lockwashers (25) and screws (26).
10. Install circuit 6N lead (23) to shunt (27) and secure with new lockwasher (28) and screw (29).