TM 9-2350-277-20-3
REPLACE GENERATOR FIELD PRESSURE SWITCH
0323 00
THIS WORK PACKAGE COVERS:
Removal (page 0323 00-1)
Inspection and Repair (page 0323 00-1)
Installation (page 0323 00-2)
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Sealing compound (WP 0928 00, Item 56)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Drivers power plant access panel
removed (see your -10)
REMOVAL
1.
Disconnect circuit 1A/1B lead (1) from generator field switch (2).
2.
Remove switch (2) from tee (3) on secondary fuel filter (4).
3.
Check circuit lead. Replace worn or cracked lead and damaged connector (WP 0382 00).
INSPECTION-ACCEPTANCE AND REJECTION CRITERIA
1.
Check circuit lead. Replace worn or cracked lead and damaged connector WP 0382 00
0323 00-1