TM 9-2350-277-20-3REPLACE GENERATOR FIELD PRESSURE SWITCH 0323 00THIS WORK PACKAGE COVERS:Removal (page 0323 00-1)Inspection and Repair (page 0323 00-1)Installation (page 0323 00-2)INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsSealing compound (WP 0928 00, Item 56)Personnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Driver’s power plant access panelremoved (see your -10)REMOVAL1. Disconnect circuit 1A/1B lead (1) from generator field switch (2).2. Remove switch (2) from tee (3) on secondary fuel filter (4).3. Check circuit lead. Replace worn or cracked lead and damaged connector (WP 0382 00).INSPECTION-ACCEPTANCE AND REJECTION CRITERIA1. Check circuit lead. Replace worn or cracked lead and damaged connector WP 0382 000323 00-1