TM 9-2350-277-20-3REPLACE FUEL RETURN PRESSURE TRANSDUCER — Continued 0325 00INSTALLATION1. Apply a thin coat of adhesive to threads of transducer (3).2. Connect transducer (3) to tee (4).3. Connect fuel return pressure transducer lead (1) to STE/ICE wiring harness (2).FOLLOW-THROUGH STEPS1. Lower power plant grill (WP 0464 00).2. Install air cleaner (WP 0168 00).3. Close power plant front access door (see your -10).4. Raise trim vane (see your -10).END OF TASK0325 00-2