TM 9-2350-277-20-3
REPLACE FUEL RETURN PRESSURE TRANSDUCER Continued
0325 00
INSTALLATION
1.
Apply a thin coat of adhesive to threads of transducer (3).
2.
Connect transducer (3) to tee (4).
3.
Connect fuel return pressure transducer lead (1) to STE/ICE wiring harness (2).
FOLLOW-THROUGH STEPS
1.
Lower power plant grill (WP 0464 00).
2.
Install air cleaner (WP 0168 00).
3.
Close power plant front access door (see your -10).
4.
Raise trim vane (see your -10).
END OF TASK
0325 00-2