TM 9-2350-277-20-3
REPLACE INSTRUMENT PANEL BATTERY-GENERATOR GAUGE WIRING HARNESS
(ALL EXCEPT M981A3) Continued
0289 00
INSTALLATION
1.
Install harness lead (16) through hole in top of distribution box (12). Secure harness lead and circuit 450A lead (15) to
bus bar (17) with new lockwasher (14) and screw (13).
2.
Install master switch panel (11) on distribution box (12). Secure with eight screws (10), washers (9), and new
locknuts (8).
3.
Connect circuit 27E lead (5) to battery generator gage (6).
4.
Connect circuit 10 lead (3) to instrument panel circuit breaker (4).
5.
Connect circuit 15 lead (1) to panel wiring harness (2).
FOLLOW-THROUGH STEPS
1.
Connect tachometer and speedometer to instrument panel gages (WP 0859 00) and (WP 0862 00).
2.
Connect battery ground strap (WP 0337 00) or (WP 0338 00).
3.
Turn MASTER SWITCH to ON (see your -10). Check that battery generator gage operates properly.
4.
Turn MASTER SWITCH to OFF (see your -10).
END OF TASK
0289 00-3/4 blank