TM 9-2350-277-20-3REPLACE BILGE PUMP CIRCUIT BREAKERS (ALL EXCEPT M981A3) — Continued 0275 004. Remove four locknuts (12), screws (13), and two circuit breakers (8) and (11) from distribution box (5). Discard locknutsINSTALLATION1. Install two circuit breakers (1) and (2) in distribution box (3). Secure with four screws (4) and new locknuts (5).2. Connect circuit 450C lead (6) and circuit 450B lead (7) to rear bilge pump circuit breaker (2).3. Connect circuit 450A lead (8) and circuit 450 lead (9) to front bilge pump circuit breaker (1).0275 00-2