TM 9-2350-277-20-3
REPLACE/REPAIR DISTRIBUTION BOX (M981A3 ONLY) Continued
0273 00
15. Connect electrical connector (1) inside front cover.
16. Route lead (2) through grommet and into front cover. Connect lead to voltmeter terminal and install new lockwasher (4)
and nut (5). TORQUE NUT TO 13.0 +/- 0.5 LB-IN. (1.5 +/- 0.06 N m).
17. Route two leads (6) and (7) through grommets and into front cover. Connect leads to switch S2 bus bar (8). Install bolt
(9), washer (10), and nut (11).
18. Route circuit 49 lead (12) through grommet and into front cover. Connect lead to switch S1 upper terminal bus bar (13).
Install bolt (14), washer (15), and nut (16).
19. Route circuit 400 lead (17), voltage regulator lead (18), circuit 3 lead (19), circuit 2 lead (20), and circuit 6B lead (21)
through grommets and into front cover. Connect leads to switch S1 lower terminal bus bar (22). Install bolt (23), washer
(24), and nut (25).
20. Route lead (26) through grommets and into front cover. Install washer (27), lead (26), washer (27), and nut (28) to upper
post of switch S3.
0273 00-17