TM 9-2350-277-20-3
REPLACE/REPAIR DISTRIBUTION BOX (M981A3 ONLY) Continued
0273 00
9.
Remove nut (1), lockwasher (2), and lead (3) from UTILITY socket J2 (4). Remove screw (5), washer (6), and
lockwasher (7) securing socket cap and chain (8) to front cover. Discard lockwashers.
10. Remove nut (9), lockwasher (10), washer (11), and screw (12). Separate UTILITY socket J2 (4) from front cover.
Discard lockwasher.
11. Remove screw (13) from EMERGENCY switch S3 handle (14). Pull handle (14) from switch S3 (15).
12. Remove two locknuts (16), washers (17), and screws (18). Pull EMERGENCY switch S3 (15) from front cover. Discard
locknuts.
13. Remove screw (19) from EQPT BAT switch S2 handle (20). Pull handle (20) from switch S2 (21).
14. Remove two locknuts (22), washers (23), and screws (24). Pull EQPT BAT switch S2 (21) from front cover. Discard
locknuts.
15. Remove two nuts (25) and lockwashers (26) from EQPT BAT voltmeter M1 (27). Retain lockwashers.
16. Remove retainer (28) and pull EQPT BAT voltmeter M1 (27) from front cover.
17. Remove screw (29) from VEHICLE BAT switch S1 handle (30). Pull handle (30) from switch S1 (31).
18. Remove two locknuts (32), washers (33), and screws (34). Pull VEHICLE BAT switch S1 (31) from front cover. Discard
locknuts.
19. Remove four locknuts (35), washers (36), and screws (37) from AUX PWR lead assembly J1 (38). Discard locknuts.
20. Pull AUX PWR lead assembly J1 (38) and lead from front cover.
21. Remove eight rivets (39) and four clips (40) from front cover.
22. Remove 20 nuts (41), lockwashers (42), and screws (43) from 10 catches (44). Separate catches from front cover.
Discard lockwashers.
23. Remove 10 grommets from front cover.
0273 00-7