TM 9-2350-277-20-3REPAIR DISTRIBUTION BOX (M113A3, M901A3, M1059A3, M1064A3, AND M58 ONLY) —Continued0270 00NOTEDo Step 2 and Step 3 for M113A3 carriers with water/ration heater kit installed only.2. Disconnect circuit lead 222B (8) from water/ration heater circuit breaker (9).3. Remove circuit lead 222B (8) and grommet (10) from distribution box (6).4. Remove circuit leads 2 (11), 2A (12), and two grommets (13) from distribution box (6).5. Remove screw (14), lockwasher (15), and lead 450C (16) from bus bar (5). Discard lockwasher.NOTEDo Step 6 and Step 7 for M113A3 carriers with water/ration heater kit installed only.6. Remove lead 222A (17) from bus bar (5).7. Disconnect lead 222A (17) from water/ ration heater circuit breaker (9). Remove lead 222A from distribution box.0270 00-2