TM 9-2350-277-20-2
REPLACE AUXILIARY TANK Continued
0230 00
3.
Remove screw (8), washer (9), lockwasher (10), bracket (11), two hooks (12), and filler cap (13) from filler neck (14).
Discard lockwasher.
4.
Remove three screws (15), washers (16), lockwashers (17), filler neck (14), and gasket (18) from auxiliary tank (3).
Discard gasket and lockwashers.
INSTALLATION
1.
Apply thin coat of sealing compound to both sides of new gasket (1).
2.
Install gasket (1) and filler neck (2) on auxiliary tank (3). Secure with three screws (4), washers (5), and new
lockwashers (6).
0230 00-2