TM 9-2350-277-20-2DRAIN AND FILL COOLING SYSTEM — Continued 0227 00FILL COOLING SYSTEMCAUTIONIf not filling coolant system immediately, tag master switch to warn others that engine coolanthas been drained.NOTEUse coolant in system at all times. It will reduce corrosion in engine block and cooling systemparts. Ethylene glycol coolant will provide low temperature protection. Mix coolant and cleanwater based on protection label on container.When filling the auxiliary tank, add coolant slowly to allow trapped air to escape.1. Fill system with coolant. Bring coolant level to COLD mark of filler neck.2. Install coolant filler cap (4) on auxiliary tank (5).3. Close coolant filler cap cover (6) on power plant grill (7).CAUTIONDo not operate engine if temperature is 230F (110C) or above. Serious engine damage willoccur.4. Start and run engine until operating temperature of 180to 230F (82to 110C) is reached.0227 00-4