TM 9-2350-277-20-2REPLACE EXHAUST EVACUATOR VALVE AND CONNECTOR — Continued 0175 005. Move air cleaner (5) in position. Secure air cleaner to sponson with three screws (8) and washers (9). TIGHTENSCREWS TO 32-34 LB-FT (43-46 N m) TORQUE. USE TORQUE WRENCH.6. Install support (10), two screws (11), new lockwashers (12), and flat washers (13).7. Slide hose (3) on valve onto air cleaner adapter (14). Secure hose with two clamps (4).FOLLOW-THROUGH STEPS1. Lower power plant grill (WP 0464 00).2. Close power plant front access door (see your –10).3. Raise trim vane (see your –10).END OF TASK0175 00-3/4 blank