TM 9-2350-277-20-2
REPLACE EXHAUST EVACUATOR VALVE AND CONNECTOR Continued
0175 00
5.
Move air cleaner (5) in position. Secure air cleaner to sponson with three screws (8) and washers (9). TIGHTEN
SCREWS TO 32-34 LB-FT (43-46 N m) TORQUE. USE TORQUE WRENCH.
6.
Install support (10), two screws (11), new lockwashers (12), and flat washers (13).
7.
Slide hose (3) on valve onto air cleaner adapter (14). Secure hose with two clamps (4).
FOLLOW-THROUGH STEPS
1.
Lower power plant grill (WP 0464 00).
2.
Close power plant front access door (see your 10).
3.
Raise trim vane (see your 10).
END OF TASK
0175 00-3/4 blank