TM 9-2350-277-20-2
REPLACE EXHAUST EVACUATOR VALVE AND CONNECTOR Continued
0175 00
5.
Move air cleaner against power plant. Remove connector (13) and valve (10) from muffler (14). Separate connector and
valve. Remove clamps (8) and hose (9) from valve.
INSTALLATION
1.
Join valve (1) and connector (2). Install hose (3) on valve (1). Install clamps (4) and valve (1).
2.
Move air cleaner (5) against power plant. Install connector (2) and valve (1) on muffler (6).
NOTE
The position of the lettering may be within ± 1.5 inch (3.81 cm) of the top.
3.
Rotate valve (1) and connector (2) until the lettering is on the top and the drain is on the bottom.
4.
Secure connector (2) to muffler (6) and valve (1) with two new clamps (7).
0175 00-2