TM 9-2350-277-20-2REMOVE/INSTALL POWER PLANT ASSEMBLY — Continued 0156 00NOTEMake sure spacer plate (half ring) stays in right side of transmission mount when power plantassembly is removed.26. Remove power plant assembly from carrier and place on blocks (WP 0157 00). Have helper assist.INSTALLATIONWARNINGDamaged lifting slings can fail with load. Soldiers can be killed or injured. Inspect all slings(WP 0673 00) before use. Do not use damaged slings.WARNINGHanging loads can kill or injure you. Keep away from hanging loads and overhead equipment.Keep hands out of compartment while power plant is being lifted for removal or lowered forinstallation.1. Attach power plant lifting sling (3) to power plant. Have helper assist.0156 00-13