TM 9-2350-277-20-2PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDINGLUBRICATION INSTRUCTIONS — Continued0155 00Table 19. Annual Unit Level Preventive Maintenance Checks and Services for M113A3 FOVITEMNO.INTERVALMAN-HOURITEM TO BECHECKED ORSERVICEDCREWMEMBERPROCEDUREEQUIPMENTNOT READY/AVAILABLEIF:105Annual0.1Carriera. Lubricate tachometer and speedometer shaftsannually with GIA. See Tachometer andSpeedometer Shaft Lubrication Table (Table 11,page 0155 00-26).1) Disconnect shafts at both ends(WP 0432 00), remove slotted washers fromdrive ends of cores, and remove cores frominstrument panel end of shafts. Clean andlubricate cores with GIA, insert cores inshafts. Install slotted washers, and connectboth end of shafts. If tachometer adapterhas a grease fitting, lubricate sparingly withlubricant GIA.b. Clean, inspect and lubricate cores. Insert coresin shafts. Install slotted washers and connectboth ends of shafts. If tachometer adapter has agrease fitting, lubricate sparingly with GIA.SPEEDOMETERSHAFTTACHOMETERSHAFT0155 00-175