TM 9-2350-277-20-2PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDINGLUBRICATION INSTRUCTIONS — Continued0155 00ITEMNO.INTERVALMAN-HOURITEM TO BECHECKED ORSERVICEDCREWMEMBERPROCEDUREEQUIPMENTNOT READY/AVAILABLEIF:e. Test specific gravity ofbatteries. See TM 9-6100-200-14.f. Clean vent holes in cell caps. Replace missingor damaged caps.g. Clean terminals, posts, and bolts (WP 0340 00).h. Tighten terminals and bolts with care to avoiddamage to batteries. Apply light coat of grease(WP 0928 00, Item 12) to terminals.POSTSBOLTSTERMINALSCELL CAPS015500-125