APU HOUR METER WIRING HARNESS
Section IV SIMPLIFIED TEST EQUIPMENT FOR INTERNAL COMBUSTION ENGINE POWERED MATERIEL (STE/lCE)
TM-9-2350-267-20 Carrier Ammunition Tracked M992 (2350-01-110-4660) Manual
Page Navigation
682
683
684
685
686
687
688
689
690
691
692
APU
GENERATOR
GROUND LEAD (12329662): REMOVAL AND INSTALLATION
REMOVAL
I
WARNING
Turn OFF MASTER switch. Disconnect battery.
A
B
C
D
Remove air intake plenum (p 13-1).
Remove nut (1), lockwasher (2) and flat washer (3) from terminal E of
generator
terminal box (4). Discard lockwasher.
Disconnet cable (5) GND connector from harness 12329650 (6) GND
connector.
Remove cable (5) from APU
INSTALLATION
NOTE
Seal all exposed terminals with silicone sealant
adhesive (item 5, Appx D).
Reverse removal procedures using new lockwasher.
I
I
I
6-145/(6-146 blank)