APU HOUR METER WIRING HARNESS (12329660): REMOVAL, DISASSEMBLY, ASSEMBLY AND INSTALLATION
REMOVAL
A
B
c
D
E
F
G
H
WARNING
Turn OFF MASTER switch. Disconnect battery
ground cables.
NOTE
Removal of left projectile rack is required (TM 9-
2350-267-10).
Remove APU compartment access plate (p 13-13).
Remove APU intake plenum (p 13-1).
Remove engine cylinder shroud door panel.
Remove from each fuel solenoid terminal one nut (l), lockwasher (2)
and flat washer (3). Discard lockwasher.
Disconnect harness (4) from fuel solenoid (5).
Disconnect harness (4) connectors from APU hour meter (6).
Remove two screws and two clamps (7).
Remove harness (4) from APU.
6-143
Change 4
TM 9-2350-267-20