Equipment Condition:AFES MANUAL DISCHARGE SYSTEM: CABLE ADJUSTMENT PROCEDUREINITIAL SETUP ADJUSTMENTAFES deactivated (p 14-14.3).Actuator assembly cover removed (p 14-52.20).ABCDEFRemove slack from bottom cable (3) at actuator block (1) actratorassembly (2). Set adjustment nut (4) againstactuator block (1). Turn lockkingnut (5) until flush against ajustment nut.Remove slack from middle cable (6). Set adjustment nut (7) for a 1/32-inchgap to actuator block (1). Tighten locking nut (8).Remove slack from top cable (9). Set adjustment nut (10) for a 1/8-inch gapto actuator block (1). Tighten locking nut (11).Remove slack from handle cable (12). Adjust cable length for a 1/4 to 1/2-inch gap between the handle retaining springs (13) and packing nut (14).Secure actuator assembly end of cable to pin (15) by tightening setscrew (16).Cut off exeess handle cable (12) length inside actuator assembly (2) to leave3/8 to 1/2 inch beyond pin (15).Install fire extinguisher seal (17) through nut (14) and around handle (18).14-55Change 4TM 9-2350-267-20
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business