TM 9-2350-261-34R E P L A C E I N F R A R E D P O W E R S U P P L Y C A B L E A S S E M B L YD E S C R I P T I O NThis task covers:Remove (page 6-9).Install (page 6-10).I N I T I A L S E T U PTools:References (cent):General Mechanics Tool Kit (Item 35, App B)See your -20Personnel Required:Equipment Conditions:Track Vehicle Repairer 63H10Engine stopped/shutdown (see your -10)Carrier blocked (see your -10)References:Battery ground lead disconnectedSee your -10(see your-20)R E M O V EW A R N I NGHigh voltage in the M19periscope can cause seriousinjury or death. Voltagecould exceed 16,000 volts.To avoid accidents, observethe following1.2.Always connect power cable to periscopebefore turning MASTER SWITCH andinfrared (I.R.) POWER switch to ON.Before disconnecting power cable fromM19 periscope, always wait at least twominutes after turning infrared (I.R.)POWER switch and MASTER SWITCHOFF.Do not disconnect power cable untilimage disappears from periscope screen.Never touch end of power cable, or allowit to contact metal surfaces.If circuit 517 lead (1) is in stowed position,disconnect it from the top of power supplyassembly (2) and master switch paneldummy connector (3).If circuit 517 lead (1) is in operating position,disconnect it from the top of power supplyassembly (2) and bottom of periscope (4).GO TO NEXT PAGE6-9