TM 9-2350-261-20-4
REPLACE CABLE W45 (M1068 ONLY) -- Continued
0754 00
INSTALLATION
1.
Position cable W45 (1) in carrier. Connect cable plug W45 P13 (2) into power control enclosure jack A1 J33 (3).
2.
Connect cable plug W45 P1 (4) into DC power extension box jack A9 J2 (5).
3.
Connect cables with screw (6) and clamps (7) to bulkhead.
4.
Secure cables with three screws (8) and clamps (9) to bulkhead.
5.
Secure remaining cable W45 with six new tie straps (10) evenly between clamps (9).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
END OF TASK