TM 9-2350-261-20-4
REPLACE CABLES W42, W43, AND W251 (M1068 ONLY)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Equipment Condition
Maintenance Level
Engine stopped (see your -10)
Unit
Carrier blocked (see your -10)
Tools and Special Tools
All external power disconnected (TM 11-7010-256-
12&P)
Battery ground lead disconnected (WP 0294 00)
Materials/Parts
Tie strap (6)
Personnel Required
Power-Generation Equipment Repairer 52D10
REMOVAL
1.
Release catch (1) and open cover (2) on power supply storage box (3).
2.
Disconnect cable W251 plug P1 (4), cable W42 plug P1 (5), and cable W43 plug P1 (6) from UPS (7). Remove cables
from opening (8) in back of power supply storage box (3).
3.
Remove six tie straps (9) from cables (10). Discard tie straps.
4.
Disconnect cable W251 plug P2 (11) from UPS power extension box A18 jack J6 (12).
5.
Disconnect cable W42 plug P2 (13) from DC power extension box A8 jack J21 (14).
6.
Disconnect cable W43 plug P2 (15) from AC power extension box A7 jack J6 (16).
7.
Remove cables W251 (17), W42 (18), and W43 (19) from carrier.