TM 9-2350-261-20-4
REPLACE POWER DISTRIBUTION CABLE (W3) (M1068 ONLY)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Personnel Required
Maintenance Level
Power-Generation Equipment Repairer 52D10
Unit
Equipment Condition
Tools and Special Tools
Engine stopped (see your -10)
Carrier blocked (see your -10)
Materials/Parts
All external power disconnected (TM 11-7010-256-
Tie strap (6)
12&P)
Battery ground lead disconnected (WP 0294 00)
REMOVAL
1.
Disconnect W3 cable plug P3 (1) from jack J24 (2) on power control enclosure A1 (3).
2.
Remove four screws (4) and clamps (5) from hull weldnut. Remove clamps (5) from harness W3.
3.
Cut six tie straps (6). Discard tie straps.
4.
Disconnect W3 cable plug P1 (7) from jack J1 (8) on power distribution box A3 (9).
5.
Remove cable W3 (7) from carrier.