TM 9-2350-261-20-4
REPLACE EXTERNAL COMMUNICATION BOX A11 (M1068 ONLY)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Equipment Condition
Maintenance Level
Engine stopped (see your -10)
Unit
Carrier blocked (see your -10)
Tools and Special Tools
All external power disconnected (TM 11-7010-256-
12&P)
Battery ground lead disconnected (WP 0294 00)
Materials/Parts
Tie strap (3)
Personnel Required
Signal Support System Specialist 31U10
Helper (H)
REMOVAL
NOTE
Tag all cables for identification before removing them. Replace pads only if damaged.
1.
Disconnect cable W101 (2) from J1 and cable W102 (3) from J4 and from curbside data panel assembly (1).