TM 9-2350-261-20-4
REPLACE AC POWER EXTENSION BOX A19 (M1068 ONLY)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Equipment Condition
Maintenance Level
Engine stopped (see your -10)
Unit
Carrier blocked (see your -10)
Tools and Special Tools
All external power disconnected
(TM 11-7010-256-12&P)
Battery ground lead disconnected (WP 0294 00)
Materials/Parts
Locknut (4)
Personnel Required
Power-Generation Equipment Repairer 52D10
REMOVAL
1.
Disconnect cable W252 (1) from connector J15 (2) on A.C. power extension box A19 (3).
2.
Remove four screws (4), washers (5), locknuts (6), and A.C. power extension box A19 (3) from mount (7). Discard
locknuts.