TM 9-2350-261-20-4
0700 00
(M1059 ONLY) -- Continued
REMOVAL
WARNING
Before you do any maintenance, discharge all capacitors to ground or electrical shock could
injure personnel.
1.
Disconnect cable assembly (1) from control panel connector 1J2 (2).
2.
Disconnect cable assembly (1) from air compressor cable assembly connector (3).
3.
Remove six screws (4), lockwashers (5), clamps (6), and cable assembly (1) from carrier hull. Discard lockwashers.