TM 9-2350-261-20-4
REPLACE M8A3/M13 AIR PURIFIER/PRECLEANER AND FRAME
0678 00
(M577A2 ONLY) -- Continued
INSTALLATION
NOTE
Air purifier/precleaner must be adjusted before installation. See TM 3-6680-316-10.
1.
Install frame assembly (1), four screws (2), eight washers (3), and four new locknuts (4) on panel.
2.
Place air purifier/precleaner (5) in frame assembly (1) and close latch (6).
3.
For M8A3 air purifier, install four hose quick disconnect fittings (8) on air purifier (5). For M13 precleaner, install two
clamps (7) and couplings (9) on precleaner and tighten clamps.
4.
Connect power cable (10) to air purifier/precleaner (5).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
END OF TASK