TM 9-2350-261-20-1Table 2-1. Unit Level Preventive Maintenance Checks and Services for M113A2 FOVItem Interval Item ToNo.BeInspectedProcedureNot MissionCapable If:4Semi-GovernedRun engine at 800 rpm for 3-5 minutesAnnual No-Loadwith range selector in 2-3 range andTestbrakes locked until normal operatingtemperature is reached.If outside air temperature is less than85° F (29°, normal operating tem-perature should be 160° to 200° F (71°to 93°C If outside air temperature isgreater than 85° (29°C, normal oper-ating temperature should he 160° to230° F (71° to 110°C.With engine quick-disconnect lever inNEUTRAL, slowly open throttle con-trol until accelerator is fully de-pressed.When you suspect a faulty gover-nor, do not exceed 3,000 rpm en-gine speed for more than 2 or 3seconds.Engine speed may exceed 3,000 rpmGovernor cuts inmomentarily, but should stabilize atand out, or surges at2,925 to 2,975 rpm.this speed, adjust-5S e m i - S t a llments are needed.The stall check will tell you if theAnnualCheckpower plant is producing maximumNotify higher main-tenance level.power. If it is not, the check will tellyou whether the engine or transmis-sion is at fault.NOTEIf check fails and a faulty tachom-eter is suspected, verify tachom-eter reading by performing STE-ICE check number 10 (page 3-284) before sending to next higherleve1 of maintenance.Run engine at 800 rpm for 3-5 minuteswith range selector in 2-3 range andbrakes locked until normal engine op-erating temperature is reachedIf outside air temperature is less than85° C (29° C), normal operating tem-perature should be 160° to 200° F (71°to 93° C).2-44 Change 4