TM 9-2350-261-20-1
1. Turnoff all power from SICPS system (see your -10
and TM 11-7010-256-12&P).
2. Remove ten screws (1), lockwashers (2), and lower
faceplate (3) of power enclosure (4).
3. Measure resistance of circuit 17B between reversing
contactor reverse terminal T1 (5) and circuit breaker
CB10 terminal 1 (6). Also measure resistance of circuit
17A between terminal T1 and forward terminal T1 (7).
4. Does multimeter read 0 ohms for both readings?
1. Faulty lead 17A and/or lead
17B.
2. Notify your Supervisor.
3-226.98
Change 3