TM 9-2350-261-20-1
1. Remove cable W40 plug P1 (1) from DC Power
Extension Box A8 jack J17 (2).
2. Turn MASTERSWITCH to ON (See your -10).
3. Set DC RIGHT OUTLETS switches (3) on Power Con-
trol Enclosure to ON (see TM 11-7010-256-12&P).
4. Measure voltage between sockets A and B of J17 (2).
5. Does multimeter read 22 volts DC or more?
1. Turn MASTER SWITCH to OFF (see your -10).
2. Disconnect cable W40 plug P2 (1) from Single Point
LAN Ground Box A15 jack J1 (2).
3. Measure resistance between plug P1 (3) pin A and P2
(1) pin A of cable W40. Repeat measurement for pins B.
4. Does multimeter read 0 ohms for each measurement?
1. Go To: No Power From DC
Power Extension Box A8
(page 3-226.31).
2. Verify no faults found.
1. Replace cable W40
(page 40.1-86).
2. Verify no faults found.
1. Repair LAN Ground Box A15 (page 40.1-16).
2. Verify no faults found.
3-226.44
Change 3