TM 9-2350-261-20-1
1. Remove circuit 28 plug (1) from fuel tank jack (2).
2. Turn MASTER POWER switch to ON.
3. Does fuel indicator read full?
1. Repair circuit 28 lead to
fuel tank sender
(page 14-3 ).
2. Verify no faults found.
1. Install jumper wire between circuit 28 plug and
ing unit
1. Replace fuel quantity send-
ground.
2. Does fuel quantity gage fail to read empty?
(page 6-9 or 6-32).
2. Verify no faults found.
1.
2.
3.
4.
5.
6.
Turn MASTER POWER switch to OFF.
Remove instrument panel for access (page 11-2).
Remove circuit 27A plug (1) from fuel quantity
gage jack (2).
Remove circuit 27 plug (3) from instrument panel
circuit breaker jack (4).
Measure
continuity
between circuit 27 plug (3) and
circuit 27A plug (1).
Does
multimeter
read 0 ohms?
1. Replace fuel quantity gage (page 11–11).
2. Verify no faults found.
1. Repair instrument panel
cable assembly
(page 14–9).
2. Verify no faults found.
3-137