E N G I N E C R A N K S B U T W I L L N O T S T A R T B E L O W 4 0 ( A I R B OX H E A T E R I S U S E D ) CONT. - TM-9-2350-261-20-1_235
E N G I N E R U N S R O U G H , S T A L L S , O R D O E S N O T P U T O U T F U L L P O W E R
TM-9-2350-261-20-1 Carrier Personnel Full Tracked Armored M113A2 2350-01-068-4077 Carrier Command Post Light Tracked M577A2 2350-01-068-4089 Manual
Page Navigation
202
203
204
205
206
207
208
209
210
211
212
TM 9-2350-261-20-1
Remove air box heater switch (page 11-7).
Remove circuits 406 (1) and 27C (2) plugs from air
box heater switch jacks (3) and (4).
Measure
resistance
between switch jack (3) and (4
with air box heater ON.
Does
multimeter
read 0 ohms?
1.
2.
3.
4.
Remove circuit 27 plug (1) from instrument panel
circuit breaker (2).
Measure
resistance
between instrument panel
wiring harness circuit 27 (1) and 27C (3) plug
pins.
Does
multimeter
read 0 ohms?
1.
2.
3.
1. Replace air box heater
switch (page 11-7).
2. Verify no faults found.
1. Repair front main harness circuit 406 (page 14-3).
2. Verify no faults found.
1. Repair instrument panel
wiring harness circuit
27C/27 (page 14-3).
2. Verify no fault found.