Table 2-1. Unit Level Preventive Maintenance Checks and Services for M113A2 F’OVItemIntervalItem ToProcedureNot MissionNo.BeCapable If:Inspected37Semi-RampPerform chalk test (page 2-37). Re-AnnualDoor,place leaky ramp door seal (pageSeal, and25-32).CatchCheck door for smooth operation. IfDoor fails to lock inhinges bind, notify higher level ofany position.maintenance.Repair catch if doordoes not lock in open position (page25-33).Adjust handle if door does not sealtightly in closed position (page 25-34).Change 3 2-63TM 9-2350-261-20-1